MSF Shaft Reconditioning In Furnace

Industry Type

Steel

Product Group

Lotherme

OUR SOLUTION
Problem

Wear

Dimensions & Weight

3000L x 200Dia

Previous Solution

Overlaying

Our Product Used

LothermeGS 602

Size (mm)

2.4mm

Quantity (Kgs)

40

JOB PICTURES
Job Pic Before Repair
Job Pic After Repair
ANALYSIS
Equipment Name

Furnace

Base Metal

15Mo3

Material Handled

Molten Iron

Temp (Deg.C)

750-800

Wear Factor

Temp, Abrasion

Procedure

-Clean area of shaft surface and removing hook from shaft as mentioned in below picture.

-Pre heat the job 250deg before welding

-Follow GMAW process using Our Product LoTherme GS602 and maintain inerpass temp.

-Build up on shaft to its original dimension

-Slow cooling required after welding.

-Machining